Jobs und Karriere     CLAROS
Deutsch

Polymetron 8810 8810 sulphide analyser, basic unit, 19" panel mount

VERALTETER ARTIKEL

Polymetron 8810 8810 sulphide analyser, basic unit, 19
Artikel-Nr.: 368810,21240

VERALTETER ARTIKEL

Easy to setup, user-friendly programming

Reactor cleaning after each measurement cycle: electrodes life is increased, manual reactor cleaning is occasiona

Optional automatic calibration allows potential drifts adjustements

Only monthly maintenance

Use of laboratory standard methodology

Technische Daten

Anforderungen: 4 - 7 bar filtered and dried air
Anschluss (Druckluft): 4 / 6 mm tube connector
Anschluss (Probeneinlass): 12 mm barbed stem for 12 mm ID hose
Austauschbare Sensoren: Silver stick electrode, reference electrode
Breite: 482 mm
Durchflussrate: 40 - 300 L/h
Erforderlicher Probendruck: 0,5 - 6 bar
Gehäuse-Schutzklasse: IP65
Genauigkeit: ± 2 ± 3 %
Gewährleistung: 24 Monate
Gewicht: 25 kg
  25 kg approx.
Höhe (Panel): 753 mm
Kalibriermethode: Manual 2-point or 1-point Calibration methods (automatic Calibration methods to be ordered separately)
Measuring Principle 2: Automatic titration using potentiometric endpoint detection based on volumetric analysis
Messbereich: 2 - 150 mg/L
Messintervall: 5 - 999 min frei programmierbar
Methode: Measuring silver stick electrode
Niveauregulierung: Sample, reagents, calibration solution and chemical cleaning
Optionen: External dilution, automatic calibration, automatic heating device, chemical cleaning, conditioning, reagent tray, free-standing cabinet, wall mount
Probenahmemodus: Fixed or loop
Probenahmequalität: No filtration required, only in coarse particle separation
Probenströme: 1
Probentemperatur: 5 - 50 °C (41 - 122 °F)
Probenvolumen: 200 - 1000 mL per cycle
Process connection (drain): 2x Kabel-Durchführung für 2 - 6 mm Durchmesser
Prozessanschluss (Abfluss): 3 x cable glands for diameter 13 - 18 mm
Prozessanschluss (Spülwasser): 6 mm barbed stem for 6 mm ID hose
Pumpen: Peristaltic reagent pump for sample conditioning (additional peristaltic or piston pumps to be ordered separately)
Reagenzien-Verbrauch: 10 L canisters supplied with instrument
Relais: 1 collective alarm, warning or alarm system
  2 high or low limits on the concentrations
Requirement pressurized air: 4 - 7 bar filtered and dried air
Requirement rinse water pressure: 0,5 - 6 bar
Sensoren: Silver stick electrode, reference electrode type 8483B
Spannungsversorgung (Hz): 50 Hz
Spannungsversorgung (Volt): 220 V AC
Stromausgang: 0/4 - 20 mA linear, logarithmic or
bilinear programmable
Tiefe: 122 mm
Umgebungstemperatur: 5 - 55 °C
Wartungs-Intervall: 2 to 4 weeks application specific
Wartungs-Vorgaben: 1 to 4 weeks application specific